Patient Monitor With IBP, E-12, Yonker, China

(1 customer review)

250,000.00৳ 

Patient Monitor with IBP

  • Model: E-12
  • Brand: Yonker
  • Country of Origin: China
  • Warranty: 01 (One) Year
  • Delivery: Within 30 Days
  • NIBP cuff & tube, ECG cable & electrodes, 1” real color TFT screen, Resolution: 1024×768
SKU: 013 Category: Tag: Brand:

Description

  • Patient Monitor with IBP
  • Model: E-12
  • Brand: Yonker
  • Country of Origin: China
  • Warranty: 01 (One) Year
  • Delivery: Within 30 Days.

Standard accessories

  • NIBP cuff & tube
  • ECG cable & electrodes
  • SpO2 sensor
  • TEMP probe
  • Lithium-ion battery
  • Power cable
  • Operator’s manual

Display

  • 1” real color TFT screen
  • Resolution: 1024×768
  • One alarm indicator(yellow/red)
  • One working indicator(green)
  • One battery charge state indicator(green)
  • Three modes in accordance with the alarm state

Date Storage

  • Trend diagram/table: 7x24h
  • NIBP review: 400 events
  • Wave review: 100min
  • Alarm review: 100 alarm events
  • Support drug concentration titration analysis

SPO2

  • Range: 0 ~ 100%
  • Resolution: 1%
  • Precision: 70% ~ 100%: ±2 DIGIT
  • 0% ~ 69%: ±no definition given

NIBP

  • Method: Pulse wave oscillometry
  • Work mode: Manual/ Auto/ STAT
  • Measure interval of auto mode: 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
  • Measuring Time of STAT Mode: 5 minutes
  • PR range: 30 ~ 250bpm
  • Measure & alarm range: Adult (SYS 40 ~ 270mmHg, DIA 10 ~ 215mmHg, MEAN 20 ~ 235mmHg)

Pediatric (SYS 40 ~ 200mmHg, DIA 10 ~ 150mmHg, MEAN 20 ~ 165mmHg)

Neonatal (SYS 40 ~ 135mmHg, DIA 10 ~ 100mmHg, MEAN 20 ~ 110mmHg)

  • Static pressure range: 0 ~ 300mmHg
  • Precision: ± 3mmHg
  • Pressure precision: Max. average error: ±5mmHg
  • standard deviation: ±8mmHg
  • Overvoltage protection: Adult 300mmHg, Pediatric 240mmHg, Neonatal 150mmHg

IBP

  • Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measuring and alarm range
  • ART 0 ~ 300 mmHg
  • PA -6 ~ 120 mmHg
  • CVP/RAP/LAP/ICP -10 ~ 40 mmHg
  • P1/P2 -10 ~ 300 mmHg
  • Press Sensor
  • Sensitivity 5 uV/V/mmHg
  • Impedance 300-3000
  • Resolution: 1 mmHg
  • Accuracy: ±2% or ±1mmHg, which great
  • Actualization interval: about 1 Sec.