Description

- Anesthesia Machine with Isoflurane Vaporizer
- Model: S-6500A
- Brand: Superstarmed
- Country of Origin: China
- Warranty: 01 (One) Year
- Delivery: Within 30 to 45 Days.
Features
- 10.4” TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.
- Integration breathing circuit design, ensure easy operating and keep tidy.
- Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
- Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
- Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;
- Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.
- Vital sign monitor and Anesthetic gas monitor are optional.
Technical Specification:
Ventilation mode : IPPV, A/C, PCV,SIMV, SIGH, MANUAL
Ventilator parameter range
- Flowmeter : 0, (0-10 L/min), NO (0-10 L/min) or AIR (0-10 L/min)
- Rapid oxygen supply : 25 L/min-75 L/min
- Tidal volume(VI) : 0,20 ml-1500 mL
- Frequence (Freq) : 1/min-100/min
- LE : 4:1-1:8
- PEEP : 0 cmH,0-30cm40
- Pressure triggering sensitivity (PT) : -20cm-600 cm (Based on PEEP)
- Flow trigger sensitivity (FTr) : 0.5 L/min-30 L/min
- Pressure control (PC) : 5 cmH,0-60 cmH0
- SIGH : (off) 1/100-5/100
- Apnea ventilation : OFF. 55-605
- Pressure limit : 20 cm-O-100cm:0
Monitoring parameter
- Frequence (Freq) : 0 /min-100/min
- Tidal volume (VI) : 0 ml-2000 mL
- MV : 0 L/min-100 L/min
- Oxygen concentration : 15%-100%
- Ppeak : 0 cmH,0~100 cmH,0
- Cydn : 1 mL/cmH0~1000 ml/cmНО
Alarm and protection
- The AC power failure alarm: Power failure or no connection
- Low voltage alarm for back up battery: < 11.3 plus/minus 0.3 * V
- No tidal volume: <= 5mL within 6 s
- High oxygen concentration alarm: 19% + (-100) %
- Low oxygen concentration alarm: 18%-99%
- High airway pressure alarm: 20 cmH.O-100 cmHO
- Low airway pressure alarm: 0cm*H{0}*O – 20cm*H {0} *O
- High minute volume alarm: Adult (5L / m * in – 20L / m * in)
- Low minute volume alarm: Paed (1 L/min-15 L/min, 0-10 L/min)
- Continuous pressure alarm : (PEEP+ 1.5kPa ) over 165
- Suffocation warning : 55-60s no spontaneous ventilation
- The maximum limited pressure : <12.5. kPa
- Fan error : Show on screen
- Oxygen deficit : Show on screen
Working condition
- Gas source : O_{2v} N_{1}*O_{1} or AIR
- Pressure : 280kPa – 600kPa
- Voltage : 100 – 240V
- Power frequency : 50/60 Hz
Oscillogram
- P-T (pressure-time)
- F-T (flow-time)
- V-T (volume-time)
- ETCO,T (ETCO₂-time)
- P-V loop (pressure – volume loop)
- F-V loop (flow-volume loop)
- F-P loop (flow-pressure loop)